Small pixel effect

The dimension of detector is 12x12x12 mm3. Applied 1 V in z=12 plane at 5.5 Here is the weighting potential in density plot, equipotential line (green), and electric field vectors (black). It is weight potential in pixellated detector along z-axis at x = 6 mm and y = 6 mm. The shape of weighting potential is same with that of Frisch-grid and hemi-spherical detector. Now you can understand ..

Radiation Detector 2025.05.22

Weighting potential in Frisch-grid detector

Weighting potential distribution in bar-shaped (6x6x12 mm3) CdZnTeSe detector. 5-mm wide Frisch-grid band attached to below 1-mm from anode. It was easily calculated with FEM (finite element method) using Mathematica. Left side (z=0) is cathode and right side (z=12) is anode. Sometimes (in scientific paper) the location of Frisch-grid is not properly discribed. The location of Frisch-grid sho..

Radiation Detector 2025.05.07
이전
1
다음
더보기
  • 분류 전체보기 N
    • Radiation Detector
    • LaTeX
    • Python
    • Mathematica
    • Photos
    • Useful tips N
    • 맥사용자를 위한 팁
    • Profile

최근글과 인기글

  • 최근글
  • 인기글

Calendar

«   2025/05   »
일 월 화 수 목 금 토
1 2 3
4 5 6 7 8 9 10
11 12 13 14 15 16 17
18 19 20 21 22 23 24
25 26 27 28 29 30 31

Tag

CdMnTe, frisch-grid, small pixel effect, number of ehps, laser vs electron number, CdZnTeSe, finite element method, http to https, laser illumination, FEM, IEEE TNS, latex, endnote toolbar remove, language setting, 맥에서 워드 언어설정, mathematica, hemispherical detector, MnTe phase diagram, temperature profile of heater, weighting potential,

최근댓글

공지사항

  • Nuclear Instruments and Methods in Physics Researc⋯
  • Transaction on Nuclear Science - Submission

방문자수Total

  • Today :
  • Yesterday :

Copyright © SMART

kuphy1@gmail.com

티스토리툴바